RocketClip Cladding
Cladding clip RocketClip
WOCON-ROCKETCLIP-60X60MM
Register now and access more than 125,000 products
Flexible handling
- The wooden battens can be mounted both horizontally and vertically in the clips
System free from thermal bridges
Suitable for almost all types of surfaces
- CLT in combination with Assy® combi with repair washer
- Concrete, calcium silicate block, solid and perforated bricks in combination with SHARK® UR F plastic frame anchor
- The substructure must have a load capacity that is sufficient to withstand any loads that may occur
- We recommend using treated wooden battens measuring 44x44 mm
- For cladding weighing over 35 kg per m2, please consult our technical adviser
- All wood used must be at least quality class C18
- Ensure that the surface is flat. Remove anything that is sticking out and/or excess glue or mortar as far as possible
- Maximum height of up to 20 metres above ground level. For greater heights, please consult our technical adviser
Datasheets(X)
- Suitable for mounting on concrete, calcium silicate blocks, ceramic lightweight blocks, solid or perforated bricks and CLT solid wooden walls
- Suitable hard insulation panels with a pressure resistance of 120 kPa or above: EPS, PIR, Resol foam and Gutex Multitherm wooden plates. For other insulation panels, please consult a Würth technical adviser
Number of RocketClips per m²
- A cross-joint is assumed to have a maximum centre-to-centre distance (up to max. 35 kg of cladding per m²) of 600 mm horizontally and 800 mm vertically, if using vertical battens in the RocketClips.
- For a single connection using horizontal battens in RocketClips, we recommend a centre-to-centre distance of 600 mm and spacing of 600 mm
- For cladding weights over 35 kg per m², please consult a Würth technical adviser
Mounting insulation panels and RocketClips
- Always position panels according to the manufacturer's specifications
- Position the insulation panel against the substructure (securing temporarily using adhesive foam is recommended)
- Drill a hole 10 mm in diameter at least 60 mm into the substructure. Choose the appropriate drilling method and type of core drill bit for the surface. A rotary hammer drill should always be used to drill into perforated bricks. Use a hammer or impact drill for solid bricks and concrete. Not applicable for CLT substructures.
- Clean the drill hole (blow out, brush, blow out)
- Push the RocketClip extension into the insulation panel until it cannot go in any further. Use a 20 mm flat drill bit to pre-drill a hole with a depth of 30 mm in the Multitherm wooden plate
- Push the specified SHARK UR® 10 plastic frame anchor into the RocketClip extension (not applicable for CLT)
- Secure the plastic frame anchor to the substructure with a bit extender
- The length of the anchor is the insulation thickness + 20 mm
- The anchor must be inserted at least 50 mm into the substructure
- Tighten the screw until the batten bracket visibly pulls into the insulation
- In accordance with the ETA approval for the SHARK UR® plastic frame anchor, the screw heads must be coated with corrosion protection spray after installation
- Push the plastic plug-in cap supplied into the extension to ensure a watertight and airtight seal
- Where necessary, install Belleville anchors as specified by the insulation panel manufacturer so that the insulation panel is always attached to the façade with a sufficient number of attachment points
Mounting wooden battens
- We recommend using treated wooden battens measuring 44x44 mm of at least quality class C18
- Mount the planed wooden battens in the RocketClips
- The slotted hole serves as a guide to help ensure level installation and is not suitable for mounting battens permanently
- Screw two of the specified stainless steel half round head screws (4x30 mm) into the small holes on each side
Material | PA 6 GF30 HI - Polyamide glass fiber reinforced |
Width of fork | 44 mm |
Length x width x height | 60 x 60 x 94.5 mm |
Diameter of hole | 11.75 mm |
Select RAL-colour code